Radiometer logo

safePICO and PICO 70 blood gas self-fill syringes

Supporting your blood gas mixing with our self-fill arterial blood gas syringe

  • Request info

    I would like more information about Radiometer blood gas self-fill syringes


    Contact details

    Workplace details


    By submitting this form, I acknowledge that I have reviewed and understood the data privacy notice.

    All fields must be filled!

  • See more products
  • Reliable blood gas results
  • Take no more blood than necessary
  • Prevent accidental blood exposure

Improve your mixing with the safePICO self-fill blood gas syringe

With the safePICO self-fill blood gas syringe, you can improve your mixing and get results you can trust.

  • Mixing ball helps you obtain a homogeneous sample
  • safeTIPCAP minimizes the risk of blood contact
  • Barcode helps you get a correct match between your patient and blood sample
  • Integrated needle shield device minimizes the risk of needlestick injury
  • Dry electrolyte-balanced heparin reduces the risk of your sample clotting 

Types of Radiometer self-fill syringes


safePICO self-fill syringe


All the features of the safePICO self-fill syringe are designed to help you improve your mixing in the preanalytical phase.


PICO70 self-fill syringe


The PICO70 self-fill syringe is the simple version of the safePICO self-fill syringe which minimizes the risk of clot formation.

Specialists by blood

The history of Radiometer as we know it today began in 1954 when Radiometer developed the world’s first commercially available blood gas analyzer. Since then, we have refined our blood gas testing knowledge and experience and continue to advance our acute care diagnostic solutions.  

Explore the safePICO self-fill blood gas syringe

Be confident in operator safety, by minimizing the risk of needlestick injury.



 

 
 

Plunger stop at 1.5 mL

A protective feature that helps ensure that the barrel and plunger remain together.

 

Vented safeTIPCAP

Helps seal the sample immediately after blood collection, allows you to expel air bubbles, and stays on during analysis.

 

Vented safeTIPCAP

Helps seal the sample immediately after blood collection, allows you to expel air bubbles, and stays on during analysis.

 

Integrated mixing ball

Integrated mixing ball and automatic mixing enhances analytical quality through standardized mixing when used with ABL90-series and ABL800 FLEX-series, without causing hemolysis.

 

Needle shield device

Locked securely, the needle shield can be disposed securely, minimizing the risk of needlestick injury. 

 

Heparin brick

Uniquely designed, dry, electrolyte-balanced heparin brick reduces the risk of clots, negative electrolyte bias, and sample dilution.   

Explore the safePICO self-fill syringe

Get support on your mixing with our self-fill blood gas syringe



 

Pre-barcoded

Pre-barcoded self-fill syringe - helps ensure correct patient-sample identification every time when used as a part of the 1st Automatic solution.

 

Vented safeTIPCAP

Helps seal the sample immediately after blood collection, allows you to expel air bubbles, and stays on during analysis.

 

Integrated mixing ball

Together with automatic mixing, it enhances analytical quality through standardized and homogenous mixing, and reduces the risk of hemolysis.

 

Needleshield device

Securely locked and operated with one hand, the needleshield can be disposed securely, minimizing the risk of needlestick injury.

 

Heparin brick

Uniquely designed, dry, electrolyte-balanced heparin brick reduces the risk of clots, electrolyte bias, and sample dilution.

How we support you as a caregiver

At Radiometer, we believe that supporting caregivers should be a top priority in all phases of acute care testing.

The integrated needle shield device on the safePICO self-fill syringe lowers the risk of needlestick injury.

The vented safeTIPCAP limits the risk of contact wiht patient blood while helping you to safely remove air bubbles in the sample.



Manual mixing and automatic mixing

The built-in mixing ball in the safePICO self-fill syringe aids in the manual mixing of the sample.

However, when you mix your sample manually, make sure you don’t mix it too vigorously to reduce the risk of hemolysis. [1]

Using automatic mixing integrated in your blood gas analyzer aids in obtaining a homogenous sample. [1]

In fact, studies comparing manual and automatic mixing have demonstrated that automatic mixing is superior to manual mixing in producing a homogeneous sample and obtaining correct results. [1]

Barcode connects patient with sample

The safePICO self-fill syringe is already barcoded, helping you match the sample with the correct patient.

1st Automatic combines blood gas analyzers, pre-barcoded safePICO syringes and POC data management. Synergistically, these elements can easily ensure patient identification at the bedside, streamline workflow efficiency, and minimize the likelihood of misattributed or lost samples.

The PICO70 self-fill syringe

Compatible with an A-line catheter stopcock, enabling it to be attached to the arterial catheter/line


The PICO70 self-fill syringe helps you deliver a blood sample with high analytical quality.  It contains Radiometer’s uniquely formulated dry, electrolyte-balanced heparin.  It minimizes risk of clot formation in the sample.

The PICO70 self-fill syringe is available with a TIPCAP. The TIPCAP attaches to the syringe to reduce the risk of blood spillage.

Related knowledge sources 

Preanalytical blood gas errors

This handbook focuses on the preanalytical phase of blood gas testing and what you can do to minimize errors.

Scientific articles on preanalytical errors

The Radiometer-sponsored knowledge site acutecaretesting.org offers scientific articles on preanalytical errors.

Useful tips to avoid preanalytical errors in blood gas testing: pH, pCO2 and pO2

Preanalytical issues related to blood sample mixing

Preanalytical errors in point-of-care testing

References:

1. Wennecke G. Useful tips to avoid preanalytical errors in blood gas testing: electrolytes. www.acutecaretesting.org Oct 2003.

MAPSSS-000872 R1

Cookies are used on this website

Use of cookies
Confirm your account with Radiometer

Please enter a valid email

CONTINUE
By submitting your e-mail you agree to the data policy notice
Radiometer is using Microsoft Azure Active Directory to authenticate customer access. If you are already registered you will be taken to Microsoft AD to sign in using your Microsoft AD credentials.
You are already registered
Radiometer is using Microsoft Azure AD to authenticate customer access. If you are already registered you will be taken to AZURE to sign in using your AZURE credentials.
Thank you

We will be sending an e-mail invitation to you shortly to sign in using Microsoft Azure AD.

Radiometer is using Microsoft Azure AD to authenticate customer access.
Sorry

It seems that your e-mail is not registered with us

Radiometer is using Microsoft Azure AD to authenticate customer access. If your e-mail is not registered with us please click CONTINUE and we will guide you through the sign-in process.
We have previously sent an invitation by e-mail

Please click "Get started" in the e-mail to complete the registration process

Radiometer is using Microsoft Azure AD to authenticate customer access.
Sorry

We were not able to process your request due to a communication error

Sorry

It seems this account has not been given access to the portal

Radiometer is using Microsoft AZURE Active Directory to authenticate users

Radiometer uses Azure AD to provide our customers and partners secure access to documents, resources, and other services on our customer portal.

If your organization is already using Azure AD you can use the same credentials to access Radiometer's customer portal.

Key benefits

       
  • Allow the use of existing Active Directory credentials
  • Single-sign on experience
  • Use same credentials to access future services

Request access

You will receive an invitation to access our services via e-mail when your request has been approved.

When you accept the invitation, and your organization is already using AZURE AD, you can use the same credentials to access Radiometer's customer portal. Otherwise, a one-time password will be sent via e-mail to sign in.